High-power variable-speed suction, for restorative dentistry and surgery.

Source: Cattani UK & Ireland brochure, p.2
Source: Cattani documentation, depliant turbo smart hp itaeng cod 05 2023 web, p.2
Source: Cattani documentation, depliant turbo smart hp itaeng cod 05 2023 web, p.6
Source: Cattani documentation, depliant turbo smart hp itaeng cod 05 2023 web, p.4
Source: Cattani documentation, depliant turbo smart hp itaeng cod 05 2023 web, p.5
Source: Cattani documentation, manual turbo smart hp ed 06 2023, p.26
| power input | 3 kW |
| sound pressure (ducted air) | 70 dB(A) |
| chairs | 4 simultaneous |
| dimensions (W × D × H) | 510 × 370 × 770 mm |
Source: cattani.it
Consigliato per 4 studi in funzione contemporanea
Source: cattani.it

| maximum flow | 900 l/min |
| max. vacuum in continuous duty | 210 mbar |
| power input | 1.12 kW |
| sound pressure without cover | 64 to 71 dB(A) |

| maximum flow | 1000 l/min |
| max. vacuum in continuous duty | 210 mbar |
| power input | 0.95 kW |
| sound pressure (ducted air) | 59 dB(A) |

| maximum flow | 1400 l/min |
| max. vacuum in continuous duty | 210 mbar |
| power input | 1.5 kW |
| sound pressure without cover | 68.4 to 69 dB(A) |
Answers taken from Cattani documentation. Another question? A specialist will answer.
From 1 to 2 simultaneous chairs for Micro-Smart, 2 for Turbo-Smart A, 3 to 4 for Turbo-Smart B, 4 for Turbo-Smart 2V and Turbo-Smart HP, up to 5 for Turbo-Smart TS.
Source: cattani.it
Turbo-Smart A: 68.4 to 69 dB(A) without cover, 66.4 to 67 dB(A) with plastic cover, 48.5 to 49.5 dB(A) in an indoor soundproof cabinet.
Source: Cattani documentation, manual smart 04 2024, p.5
Yes. Turbo-Smart, Turbo-Smart TS, Turbo-Smart 2V, Turbo-Smart Cube, Micro-Smart and Micro-Smart Cube are controlled with the SmartApp application.
Source: Cattani documentation, manual smart 04 2024, p.32
An AxeMed Cattani specialist checks your chairs, your instruments and your equipment room.
Get advice